Capacitors: 100pF to 500uF (±2% to 20% based on capacitor
type, ±10pF) Contact
Dynalab for exact specification per capacitor type
4-wire Kelvin Mode
.005 ohms to 100 ohms: ±1%, ±.005
Ohm
Relay Testing
Capable of active relay testing
Test Voltage
14 VDC maximum (Automatically selected by the
NX Tester)
Test Current
5mA DC (Automatically selected by the NX Tester)
Test Speed
1 seconds per 1024 test points (continuity only)
3 seconds per 1024 test points (continuity and shorts)
High
Voltage
Hipot Range
50 – 1500VDC
50 – 1000VAC
Insulation Resistance Range
5 MΩ– 1 GΩ(± 10%)
General
Audible Tones
Provides a variety of user programmable tones
for error notification and special events.
Program Storage
3.3Mb of capacity with no file quantity limitation.
Control Port
24 control port capability (additional hardware
required)
Serial Ports
Two RS-232 ports (optional two additional RS-232
ports)
Test Point Interface
Din Connector (96 Position, 32 Loaded)
Input Power
100 – 240VAC, 50-60Hz external power supply
(30W Hipot, 60W Hipot+) Power supply provides 15VDC to the NX
Tester
Test Point Capacity
NX Hipot: 64 - 128 test points
NX Hipot+: 64 - 1024 test points
Size (W x D x H)
NX Hipot: 10.7” x 7.5” x 3.8”
(27.2 cm x 19.0 cm x 9.7 cm)
NX Hipot+ Display Unit: 10.7” x 2” x 3.8”
(27.2 cm x 5.1 cm x 9.7 cm)
NX Hipot+ Base Unit: 9.5” x 6.4” x 8.6” (24.2
cm x 16.3 cm x 21.9 cm)NX Hipot+ Expansion Unit: 9.5”
x 6.4” x 6.1” (24.2 cm x 16.3 cm x 15.5 cm)
Weight
NX Hipot: 7.4 lbs (3.4 Kg)
NX Hipot+ Display Unit: 2.5 lbs (1.2 Kg)
NX Hipot+ Base Unit: 13.8 lbs (6.3 Kg)NX Hipot+ Expansion Unit:
9.8 lbs (4.5 Kg)